- FOP and low power consumption
The built-in FOP and low power consumption design effectively prolong the sensor’s service life. As shown in the pic, the red X-rays from A are converted into yellow visible light after flashing, but there are still some red X-rays. After passing through FOP, there’s no red X-ray left.
* Available on VDR0507-CA0 only. VDR0507-GA0 does not include FOP.
- High resolution scintillators
The high-resolution scintillator produces more realistic HD images, and fine furcations can also be easily found.
Csl Scintillators have pin-like crystals along which light travels. Therefore, CsI sensors have higher resolution and better emission than scintillators composed of other crystals.
* VDR0507-CA0 uses CsI scintillator. VDR0507-GA0 uses GOS scintillator.
Cross-sectional photograph of CsI scintillators Needle-like crystals
* Images from actual imaging output (large dog)
- Wide dynamic range
Both low and high dose can be easily shot, which greatly reduces the requirements for filming and the possibility of film wasting, and improves the image resolution and sensitivity.
- Size 4: Versatile veterinary imaging
With a large active area, the size 4 animal sensor is suitable for dental imaging as well as selected extraoral applications, such as paws and small thoracic areas in medium and large animals.
Hamster chest cavity
Canine joint
Canine joint
- Optimized chip combination
The CMOS image sensor which is paired with an industrial-grade microfiber panel and the advanced AD-guided technology restores the real tooth picture, so that subtle root apex furcations can also be easily found with clearer and more delicate images. Besides, it helps to save about 75% of the cost compared with traditional dental film shooting.
The built-in elastic protective layer is used to alleviate the impact of external stress, which is not easy to be damaged when dropped or subjected to pressure, reducing users’ costs.
- Durable
The data cable has been tested for millions of times of bending, which is more durable and provides good quality assurance. The PU with strong tear resistance is used as the protective cover, which is easy to clean and has good bending resistance. The ultra-fine conductive copper wire has passed the rigorous bending test also ensures its durability. Handy also offers cable replacement service, freeing you from extra worries.
- Sterilizable liquid soaking
According to repeated verification by engineers, the sensor is tightly stitched and reaches the IPX7 waterproof level, able to be soaked and disinfected thoroughly to avoid secondary cross-infection.
- Twain standard protocol
The unique scanner driver protocol of Twain allows our sensors to be perfectly compatible with other software. Therefore, you can still use the existing database and software while using Handy’s sensors, removing your trouble of expensive imported brands’ sensors repair or high cost replacement.
- Powerful imaging management software
HandyVet is a special version of veterinary dentistrysoftware, with standard animal tooth maps, rich image processing tools, simple operation, easy to use. One set of software is available for all Handy Animal medical devices.
|
Model Item |
VDR0304-CA0 |
VDR0507-GA0/CA0 |
VDR1207-GA0/CA0 |
|
Image pixels |
2.65M(1888*1402) |
9.19M(2524*3640) |
22.9M(3646*6268) |
|
Dimensions (mm) |
44.5 x 33 |
77.1 x 53.8 |
75.6 x 143.8 |
|
Active area (mm) |
35 x 26 |
46.7 x 67.3 |
67.5 x 116 |
|
Scintillators |
Csl |
Csl/GOS |
Csl/GOS |
|
Pixel size (μm) |
18.5 |
||
|
Resolution (lp/mm) |
Theoretical value: ≥ 27 |
||
|
WDR |
Support |
||
|
Operating System |
Windows 2000/XP/7/8/10/11 (32bit&64bit) |
||
|
Interface |
USB 2.0 |
||
|
TWAIN |
Yes |
||